AC
Air curtain display cooler
For perfect merchandise presentation
› Air curtain for optimum cooling efficiency
› Energy efficient
› Low maintenance condenser
› Cooling cassette system
› Cassette replacement within 15 minutes (easy service)
› Night blind to save energy consumption (reed switch)
› Inside light
› Plug-in refrigeration
› Automatic defrost and condensate water evaporation
› Shelf supports can be fixed in inclined position
› Use of natural and efficient refrigerant R290 (propane)
› 100 % CFC and PFC free
EU and UK models have same specs but different electricity plugs.
AC S_UK_403784 M_UK_403785 M_EU_403761 W_UK_403786 S_EU_403760 W_EU_403762
Classification acc. EN 23953-2 M2
Climate class acc. EN 23953-2 3
Energy efficiency index EEI % 42.5 38.6 48.6 42.5 48.6
Use Display & Sale
Dimensions Gross content l 245 463 463 325 245 325
Net content l 190 324 324 250 190 250
Total display area (TDA) m² 1.00 1.72 1.72 1.20 1.00 1.20
Length Outside mm 706 716 914 706 914
Depth Outside mm 766 771 766
Height Outside mm 1,495 1,973 1,495
Shelf depth mm 1 x 388, 2 x 321
Net weight kg 144 152 135 144 135
Gross weight kg 135 165 150 135 150
Operation range Ambient Min. °C 16
temperature Max. °C 25
Relative humidity % 60 or less
Product temperature Min. °C -1
Max. °C 7
Sound pressure in 1m distance dB(A) 52.8 53.3 52.3 52.8 52.3
Blowing agent R-601 (HC) GWP 5
Daily energy consumption Edaily kWh/day 8.50 10.50 10.70 8.50 10.70
Annual energy consumption AE kWh/a 3,102.50 3,832.50 3,905.50 3,102.50 3,905.50
HVAC Rejected heat capacity W 354 438 446 354 446
Dehumidification Liter/day 0
Refrigerant Type R-290
GWP 3
Charge g 140
Max. allowable operating pressure bar 30
Power supply Voltage V 220-240
Frequency Hz 50
Nominal power acc. EN 60335-2-89 W 680 880 850 680 850
Nominal current acc. EN 60335-2-89 A 3.5 5.2 5.0 3.5 5.0
Nominal power LED W 18 25 18
Fuse protection RCBO, 30mA, C16
Cord length mm 2,500
(1) - Energy test results are declared for climate class 3, test procedure according to EN 23953-2, use of night blind for 12h, light on for 12h
(2) - With process-related interior fitting