Page 660 - General Catalogue
P. 660

AC

          Air curtain display cooler



          For perfect merchandise presentation

            › Air curtain for optimum cooling efficiency
            › Energy efficient
            › Low maintenance condenser
            › Cooling cassette system
            › Cassette replacement within 15 minutes (easy service)
            › Night blind to save energy consumption (reed switch)
            › Inside light
            › Plug-in refrigeration
            › Automatic defrost and condensate water evaporation
            › Shelf supports can be fixed in inclined position
            › Use of natural and efficient refrigerant R290 (propane)
            › 100 % CFC and PFC free



























                                       EU and UK models have same specs but different electricity plugs.
                                                AC S_UK_403784 M_UK_403785 M_EU_403761 W_UK_403786 S_EU_403760  W_EU_403762
          Classification acc. EN 23953-2                                        M2
          Climate class acc. EN 23953-2                                          3
          Energy efficiency index EEI        %        42.5            38.6           48.6      42.5      48.6
          Use                                                                Display & Sale
          Dimensions  Gross content               l   245        463       463       325       245       325
                      Net content                 l   190        324       324       250       190       250
                      Total display area (TDA)  m²    1.00       1.72      1.72      1.20      1.00      1.20
                      Length  Outside          mm     706             716            914       706       914
                      Depth  Outside           mm     766             771                      766
                      Height  Outside          mm     1,495          1,973                     1,495
                      Shelf depth              mm                            1 x 388, 2 x 321
          Net weight                            kg    144             152            135       144        135
          Gross weight                          kg     135            165            150       135        150
          Operation range  Ambient   Min.        °C                             16
                      temperature  Max.          °C                             25
                      Relative humidity          %                            60 or less
                      Product temperature Min.   °C                             -1
                                   Max.          °C                              7
                      Sound pressure in 1m distance  dB(A)  52.8      53.3           52.3      52.8      52.3
                      Blowing agent                                         R-601 (HC) GWP 5
          Daily energy consumption Edaily     kWh/day  8.50          10.50           10.70     8.50      10.70
          Annual energy consumption AE        kWh/a  3,102.50       3,832.50        3,905.50  3,102.50  3,905.50
          HVAC        Rejected heat capacity     W    354             438            446       354       446
                      Dehumidification       Liter/day                           0
          Refrigerant  Type                                                    R-290
                      GWP                                                        3
                      Charge                     g                              140
                      Max. allowable operating pressure  bar                    30
          Power supply  Voltage                  V                             220-240
                      Frequency                 Hz                              50
                      Nominal power acc. EN 60335-2-89  W  680        880            850       680       850
                      Nominal current acc. EN 60335-2-89  A  3.5      5.2            5.0       3.5        5.0
                      Nominal power LED          W     18             25             18
                      Fuse protection                                       RCBO, 30mA, C16
                      Cord length              mm                              2,500
          (1) - Energy test results are declared for climate class 3, test procedure according to EN 23953-2, use of night blind for 12h, light on for 12h
          (2) - With process-related interior fitting
          658
   655   656   657   658   659   660   661   662   663   664   665