Daikin Fresh air package - overview





         Why use VRV and ERQ condensing units for connection

         to air handling units?


         High Efficiency

         Daikin heat pumps are renowned for their high   while the outdoor air is too cold to be brought
         energy efficiency. Integrating the AHU with a heat   inside in an unconditioned state. In this case heat
         recovery system is even more effective since   from the offices is merely transferred to heat up
         an office system can frequently be in cooling mode   the cold fresh air.



                  Outside air = 10°C



                                                                            Fresh air supplied at 21°C.
                                                                            The temperature difference with
                                                                            the outdoor air is heated up efficiently
                                                                            by heat recovery via A/C system




                                                                            Indoor temperature 22°C,
                                                                            needs cooling because of solar
                                                                            radiation.
                                                                            The excessive heat can be
                                                                            transferred to the AHU.


         Fast response to changing loads
         resulting in high comfort levels          Easy Design and Installation

         Daikin ERQ and VRV units respond rapidly   The system is easy to design and install since
         to fluctuations in supply air temperature, resulting   no additional water systems such as boilers,
         in a steady indoor temperature and resultant high   tanks and gas connections etc. are required.
         comfort levels for the end user. The ultimate is    This also reduces both the total system investment
         the VRV range which improves comfort even more    and running cost.
         by offering continuous heating, also during defrost.

         Daikin Fresh air package

            › Plug & Play connection between VRV/ERQ and the entire D-AHU modular range.
            › Factory fitted and welded DX coil control and expansion valve kits.


                                                                                              VRV IV or ERQ
                                                                                              condensing unit







                                                        Factory fitted and welded
                                                        fresh air package


                                                          Electronic expansion
                                                          valve (EKEXV)                        Control box