Page 248 - Каталог
P. 248

ПОСМОТРЕТЬ ВСЕ ТЕХНИЧЕСКИЕ
                                                                                    ЧЕРТЕЖИ FXDQ-A3 НА MY.DAIKIN.EU
     3D081426C
          Подробные технические чертежи
          FXDQ40A3




                mmH O                                  mmH O  Notes
               6        60                                 6  The remote controller can be used to switch between 'high' and 'low'.
                                                             The air  ow is factory-set to 'standard'. It is possible to switch between 'standard
                                                             ESP' and 'high ESP' by remote controller setting.
               5        50                                 5
                               Upper limit of ESP High ESP  High ESP
                                            H

               4        40                                 4
                                Low      M
                                High ESP  High ESP
                       External static pressure [Pa]  Standard ESP
                                 H
               3        30       Standard ESP              3
                                 M


                            Upper limit of ESP  Lower limit of ESP
               2        20                                 2
                             Standardard ESP

                                          High ESP
               1        10                                 1
                                    Lower limit of ESP

                            Low     Standardard ESP
                            Standard ESP
                mmH O     7   8   9   10  11  12  13   mmH O
                         Air  ow rate [m³/min]
                                                                                                 3D081426C




       FXDQ50A3
          FXDQ50A3



                  [mmH O]                                     Notes
                                                      [mmH O]
                  7       70                              7   The remote controller can be used to switch between 'high' and 'low'.
                                                              The air  ow is factory-set to 'standard'. It is possible to switch between 'standard
                                                              ESP' and 'high ESP' by remote controller setting.

                  6       60                              6


                  5       50                  H           5
                              Upper limit of ESP  M High ESP  High ESP
                               High ESP
                  4       40       Standard ESP           4
                         External static pressure [Pa]
                                   H

                  3       30                              3
                              Upper limit of ESP  Lower limit of ESP
                                          High ESP
                  2       20  Standard ESP                2
                              M
                              Standard ESP
                                  Low
                  1       10      High ESP                1
                                     Lower limit of ESP

                             Low     Standard ESP
                             Standard ESP
                  [mmH O]  8   9  10  11  12  13  14  15  [mmH O]
                          Air  ow rate [m³/min]
                                                                                               3D081427C



          246
   243   244   245   246   247   248   249   250   251   252   253