Page 437 - General Catalogue
P. 437

INTRODUCTION







                                                                !     Planning your replacement in
                                                                     future?                                         AIR   PURIFIER
                                                               Monitor your system now!


                                                               Your building use might have changed
                                                               over the years. Monitoring and Daikin                  HEATING
                                                               expert advice prepare you for an
                                                               optimum replacement to maximize
                                                               efficiency and comfort, while minizing
                                                               the investment cost of your new                        SPLIT
                                                               system.




                                                                                                                      SKY AIR



          VRV-Q benefits to increase your profit


          Optimise your business                           Compare installation steps                                 VRV


          Less installation time                           Conventional solution       VRV-Q
          Tackle more projects in less time thanks to faster installation.
          It is more profitable than replacing the full system with new   1   Recover refrigerant  1   Recover refrigerant
          piping.                                          2   Remove units            2   Remove units              VENTILATION & BID-  DLE AIR CURTAINS
                                                           3   Remove refrigerant pipes  Re-use existing piping
          Lower installation costs                         4   Install new piping and wiring  and wiring
          Reducing installation costs enables you to offer customers   5   Install new units  3   Install new units
          the most cost-effective solution and improve your   6   Leak test            4   Leak test
          competitive edge.
                                                           7   Vacuum drying           5   Vacuum drying              MARINE TYPES
          Replace non-Daikin systems                       8   Refrigerant charging    6    Auromatic refrigerant
          It is a trouble-free replacement solution for Daikin systems   9   Collect contamination  charging, cleaning and
          and for systems made by other manufacturers.     10 Test operation             testing

          Easy as one-two-three
          A simple solution for replacement technology enables you                                â                   CHILLERS
          to handle more projects for more customers in less time and
          offer them the best price! Everybody wins.                                     Up to 45% shorter
                                                                                          installation time
                                                                                                                      FAN COIL UNITS

          Automatic refrigerant charge


          The unique automatic refrigerant charge eliminates the need
          to calculate refrigerant volume and ensures that the system
          will operate perfectly. Not knowing the exact piping lengths
          because of changes or mistakes in case you didn’t do the                                                   AIR HANDLING   UNITS
          original installation or replacing a competitor installation no
          longer poses a problem.

          Automatic pipe cleaning                          One touch
                                                           convenience:                                               REFRIGERATION
          There is no need to clean inside piping as this is handled     › Measure and charge
          automatically by the VRV-Q unit. Finally the test operation is   refrigerant
          performed automatically to save time.               › Automatic pipe
                                                             cleaning
                                                              › Test operation                                       CONTROL   SYSTEMS
                                                                                                             435
   432   433   434   435   436   437   438   439   440   441   442