Page 302 - Каталог
P. 302

ПОСМОТРЕТЬ ВСЕ ТЕХНИЧЕСКИЕ
                                                                                    ЧЕРТЕЖИ VAM-J НА MY.DAIKIN.EU
          Подробные технические чертежи
          VAM1000J

                 300                                                          Ultra-high speed
                          UH15                          150m      350
                 250
                         UH8                            120m      300
                         H15
                 200
               External static   pressure [Pa]  150  L15 H8  UH1  90m  250
                                                                  200
                 100  H1                                       External static   pressure [Pa]  150  UH15
                     L8                                           100
                  50                                    30m                                         UH8
                  L1                                    Ø250      50
                  0                                     Duct lenght  0                    UH1
                   400  500  600  700   800  900  1000  1100       600    700   800   900   1000   1100
                             Air  ow rate [m /h]                                Air  ow rate [m /h]
                             High speed                                        High speed
                  300                                             250
                External static pressure [Pa]  200  H15         External static pressure [Pa]  150
                  250
                                                                  200
                  150
                                                                  100
                  100
                  50
                   0                   H1          H8             50 0  L1                L8 800  L15
                    500  600    700   800   900  1000               400  500   600   700         900
                             Air  ow rate [m /h]                               Air  ow rate [m /h]
             Notes                                                         Legend
             1.The fan curves are determined with ·1/3· of the ESP on the outdoor side (·EA & OA·),       L1 = Low speed lower limit
                 and ·2/3· of the ESP on the indoor side (·RA & SA).           LB = Low speed factory setting
                                                                               L15 = Low speed upper limit
                  EA= Exhaust air                          Ultra-high speed      H1 = High speed lower limit
                  OA = Outdoor air                         High speed          H8 = High speed factory setting
                  RA= Room air                             Low speed           H15 = High speed upper limit
                  SA= Supply air                                               UH1 = Ultra-high speed lower limit
                                                                               UH8 = Ultra-high speed factory setting
             2. Measured according to ·JIS B 8628 - 2003·                      UH15 = Ultra-high speed upper limit
                                                                                                    3D112832


          VAM1500J
          VAM1500J
                  300
                        UH15                                           350         Ultra-high speed
                 External static pressure [Pa]  200  H8 UH1  UH8  L15  180m  External static pressure [Pa]  300  UH15
                  250
                        H15
                                                        150m
                  150
                                                                       250
                                                        120m
                                                                       200
                  100
                                                        90m
                      H1
                                                        60m
                   L8
                   50
                                                                       100
                                                        30m            150
                   L1                                   2xØ250                                           UH8
                   0                                    Duct length     50
                    700    900    1100  1300   1500   1700                                      UH1
                                  Air  ow rate [m³/h]                   0 700                         900                        1100  1300  1500  1700
                                                                                      Air  ow rate [m³/h]
                                High speed                             Low speed
                    300                                   250
                    250
                  External static pressure [Pa]  200  H15  External static pressure [Pa]  150 50  L15
                                                          200
                    150
                                                          100
                    100
                    50
                     0
                     700   900  1100  H1  1300  1500  1700 H8  0 700  L1  900  1100  1300  L8  1500
                                Air  ow rate [m³/h]                    Air  ow rate [m³/h]
                                                                            Legend
             Notes                                                          L1     = Low speed lower limit
             1. The fan curves are determined with ·1/3· of the ESP on the outdoor side (·EA & OA·),and ·2/3· of the ESP on the indoor side (·RA & SA·).  L8     = Low speed factory setting
                 EA = Exhaust air                                           L15   = Low speed upper limit
                 OA = Outdoor air                                           H1     = High speed lower limit
                 RA = Room air                                              H8     = High speed factory setting
             SA = Supply air                                                H15   = High speed upper limit
             2 .Measured according to ·JIS B 8628 - 2003·                Ultra-high speed   UH1   = Ultra-high speed lower limit
                                                                High speed   UH8   = Ultra-high speed factory setting
                                                                Low speed
                                                                            UH15 = Ultra-high speed upper limit      3D112838
          300
   297   298   299   300   301   302   303   304   305   306   307