Page 300 - Каталог
P. 300

ПОСМОТРЕТЬ ВСЕ ТЕХНИЧЕСКИЕ
                                                                                    ЧЕРТЕЖИ VAM-J НА MY.DAIKIN.EU
          Подробные технические чертежи
          VAM350J
          VAM350J
                     250
                                                                             Ultra-high speed
                  External static pressure [Pa]  150  UH1 L15 UH8  125m  External static pressure [Pa]  250  UH15
                                                                      300
                            UH15
                     200
                          H15
                                                                      200
                                                            100m
                                                                      150
                        H8
                     100
                                                            75m
                                                                      100
                      L8
                                                            50m
                     50 H1
                                                             25m      50 0             UH1        UH8
                      L1                                               150  200  250  300  350  400  450
                                                             Ø200
                      0                                     Duct length
                                                           450
                           150
                      100 High speed  200  250  300  350  400  Low speed      Air  ow rate [m³/h]  Ultra-high speed
                                 Air  ow rate [m³/h]
                   External static pressure [Pa]  150 0  H1  H15  External static pressure [Pa]  150 0  L1  L15  High speed
                     200
                                                          200
                                                                                             Low speed
                     100
                                                          100
                     50
                                                           50
                                                 H8
                                   300
                               250
                                       350
                           200
                       150
                            Air  ow rate [m³/h]  400  450   100  150  200  250  300  L8 350  400  450
                                                               Air  ow rate [m³/h]
                    Notes                                     Legend  Legend
                                                                  L1 = Low speed lower limit
                    1. The fan curves are determined with ·1/3· of the ESP on the outdoor side   L1 = Low speed lower limit
                    (·EA& OA·), and ·2/3· of the ESP on the indoor side (·RA & SA·).  L8 = Low speed factory setting
                    EA = Exhaust air                          L15 = Low speed upper limit
                    OA = Outdoor air                          H1 = High speed lower limit
                    RA = Room air                             H8 = High speed factory setting
                    SA = Supply air                           H15 = High speed upper limit
                    2 Measured according to ·JIS B 8628 - 2003·  UH1 = Ultra-high speed lower limit
                                                              UH8 = Ultra-high speed factory setting
                                                              UH15 = Ultra-high speed upper limit
                                                                                                   3D113493A
          VAM500J
             VAM500J
                      250
                                                           100m          Ultra-high speed
                             UH15                          80m      250
                      200
                    External static pressure [Pa]  150  UH1 H8  60m  External static pressure [Pa]  200  UH15
                            UH8
                            H15
                                                                    150
                        L15
                      100
                                                                    100
                                                            40m
                        H1
                      50
                                                                                        250
                       L1  L8                               20m     50 0 250  250  250  250  250  UH1  250  250 UH8
                                                            Ø200              Air  ow rate [m³/h]
                       0                                     Duct length
                       150  200  250  300  350  400  450  500  550  600
                                  Air  ow rate [m³/h]                                        Ultra-high speed
                              High speed                200        Low speed                 High speed
                                                                                             Low speed
                     External static pressure [Pa]  150  External static pressure [Pa]  150
                     200
                                                        100
                     100
                      50
                                                   H15
                      0             H1             H8    50 0  L1                L8  L15
                       200  250  300  350  400  450  500  550  600  150  200  250  300  350  400  450  500
                              Air  ow rate [m³/h]                Air  ow rate [m³/h]
                       Notes                                         Legend
                       1. The fan curves are determined with ·1/3· of the ESP on the outdoor   L1 = Low speed lower limit
                       side (·EA & OA·), and ·2/3· of the ESP on the indoor side (·RA & SA·).  L8 = Low speed factory setting
                       EA = Exhaust air                              L15 = Low speed upper limit
                       OA = Outdoor air                              H1 = High speed lower limit
                       RA = Room air                                 H8 = High speed factory setting
                       SA = Supply air                               H15 = High speed upper limit
                       2 Measured according to ·JIS B 8628 - 2003·   UH1 = Ultra-high speed lower limit
                                                                     UH8 = Ultra-high speed factory setting  3D113494A
                                                                     UH15 = Ultra-high speed upper limit
          298