Page 472 - General Catalogue
P. 472

Options & accessories -        outdoor
                                                                              VRV IV-Q Heat Pump Replacement VRV                     VRV III-Q Heat Recovery Replacement VRV                    VRV-W IV Water-cooled VRV
                                                                                                                                                                                           Heat Pump application   Heat Recovery application
                                                            RQYQ 140P    RXYQQ8-12   RXYQQ14-20  2-module systems  3-module systems  RQEQ 140~212  2-module systems  3-module systems  4-module systems  RWEYQ8-14  2-module systems  3-module systems  2-module systems  3-module systems
             Multi-module connection kit (obligatory)                                                                                                                                   BHFQ22P1007 /            BHFQ23P907 /
             Connects multiple modules into a single refrigerant system                           BHFQ22P1007  BHFQ22P1517             BHFP26P36C   BHFP26P63C  BHFP26P84C              BHFQ22P1517 (1)  BHFQ22P1517 (1)  BHFQ23P1357 (1)   BHFQ23P1357 (1)
             Central drain pan kit - Installs onto the underside of the outdoor unit and
             collects drain water from all bottom plate outlets into a single outlet. In cold
             areas should be heated by a field-supplied heater to prevent drain water from   KWC26B160
             freezing in the drain pan.
            Kits  Heater tape kit - Optional electrical heater to guarantee trouble-free operation
             in extremely cold and humid climates (one per outdoor unit needed)  EKBPH012T7A  EKBPH020T7A
             BHGP26A1
             Digital pressure gauge kit – displays current condensing and evaporating
             pressures in the system as Standard, or expansion valve positions and   •  •  •     1 kit per system  1 kit per system  •  1 kit per system  1 kit per system  1 kit per system
             temperature sensor data in a special service mode. Connect to the outdoor unit
             PCB, for installation in the outdoor unit.
                                                           DTA104A53/61/62
                                                          For installation into
                                                          an indoor unit: exact
             External control adapter for outdoor unit - Allows to activate Low Noise   adapter type depends   DTA104A53/61/62
             Operation and three levels of demand control, limiting power consumption via   on type of indoor unit.    For installation into an indoor unit: exact adapter type depends on type of indoor unit.    DTA104A53/61/62
             external dry contacts. Connects to the F1/F2 communication line and requires   For 14-20 HP the                   Installation in the RWEYQ outdoor unit possible.  For installation in indoor units, use appropriate type (DTA104A53/61/62) for particular indoor unit. See Options & Accessories of indoor units
             power supply from an indoor unit*, BSVQ box, or VRV-WIII outdoor unit.  demand PCB mouting   For 14-20 HP the demand PCB mouting plate is required. See Options & Accessories of indoor units
                                                          plate is required. See
            Adapters                                     Options & Accessories of
                                                            indoor units
             KRC19-26A
             Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or   •  •  •  1 kit per system  1 kit per system                                     •        1 kit per system  1 kit per system
             one BS-box of a Heat Recovery system between cooling, heating and fan only.                                                                                    (for H/P only)
             Connects to the A-B-C terminals of the outdoor unit / BS-box.
             BRP2A81                                                        •           •        1 kit per system  1 kit per system                                            •        1 kit per system  1 kit per system
             Cool/heat selector PCB (required to connect KRC19-26A to VRV IV outdoor)                                                                                       (for H/P only)
             KKSA26A560* - Cool/heat selector PCB mounting plate (only required when    •        1 kit per system  1 kit per system
             cool/heat selector PCB and Heater tape kit are combined)
             KJB111A                                                                                                                                                           •
             Installation box for remote cool/heat selector KRC19-26A  •    •           •        1 kit per system  1 kit per system                                         (for H/P only)  1 kit per system  1 kit per system
             EKPCCAB4                                                       •           •            •            •           •           •            •           •           •           •            •           •           •
            Others  VRV configurator
             KKSB2B61*
             Demand PCB mounting plate. Needed to mount Demand PCB for one or more outdoor units.  •
             DTA109A51                                         •            •           •            •            •           •           •            •           •           •           •            •           •           •
             DIII-net expander adapter
                                                                          Refnet Joints                       Refnet Headers                            Heat Recovery Branch Selector Boxes (BS-Boxes)
          Refnets & branch selector boxes
                                                          Capacity index  Capacity index  Capacity index  Capacity index  Capacity index  Capacity index  Capacity index  1-port  4-port  6-port  8-port  10-port  12-port  16-port
                                                            < 200    200 ≤ x < 290  290 ≤ x < 640  > 640  < 290  290 ≤ x < 640  > 640  BS1Q-A  BS4Q14AV1B  BS6Q14AV1B  BS8Q14AV1B  BS10Q14AV1B  BS12Q14AV1B  BS16Q14AV1B
             Metric-size connections for heat pump systems (2-pipe)  KHRQM22M20T  KHRQM22M29T  KHRQM22M64T  KHRQM22M75T  KHRQM22M29H  KHRQM22M64H  KHRQM22M75H

             Imperial-size connections for heat recovery pump (2-pipe)  KHRQ22M20T  KHRQ22M29T9  KHRQ22M64T  KHRQ22M75T  KHRQ22M29H  KHRQ22M64H  KHRQ22M75H
            Refnets

             Metric-size connections for heat recovery systems (3-pipe)  KHRQM23M20T  KHRQM23M29T  KHRQM23M64T  KHRQM23M75T  KHRQM23M29H  KHRQM23M64H  KHRQM23M75H

             Imperial-size connections for heat recovery systems (3-pipe)  KHRQ23M20T  KHRQ23M29T9  KHRQ23M64T  KHRQ23M75T  KHRQ23M29H  KHRQ23M64H  KHRQ23M75H  •

           Options for Branch selector boxes (BS box) (only  for connection with VRV heat recovery system)  KHFP26A100C                          • •       • •       • •       • •       • •       • •
             EKBSVQLNP
             Sound reduction kit (sound insulation)

             Closed pipe kit
             KHRP26A1250C
             Joint kit

             Quiet kit

          (1) For installations with special requirements towards fire regulations, the insulation material can be replaced using kits EKHBFQ1 and EKHBFQ2.    KDDN26A4  KDDN26A8  KDDN26A8  KDDN26A12  KDDN26A12  KDDN26A16
          The kits contain insulation material that complies with EN13501-1:B-S3,dO and BS476-7 (class 1)



















          470