Page 471 - General Catalogue
P. 471

INTRODUCTION



 VRV S-series  VRV IV Heat Recovery  VRV IV with continuous heating  VRV IV without continuous heating  VRV IV C+series
 2-module   3-module              2-module   3-module             2-module   3-module            2-module   3-module
 RXYSA-AV1/AY1  REYQ 8~12  REYQ 14~20  REMQ5  systems  systems  RYYQ8-12  RYYQ14-20  RYMQ8-12  RYMQ14-20  systems  systems  RXYQ8-12  RXYQ14-20  systems  systems  RXYLQ  RXMLQ  systems  systems
 Multi-module connection kit (obligatory) - Connects multiple modules into a single
 refrigerant system  BHFQ23P907  BHFQ23P1357  BHFQ22P1007 BHFQ22P1517  BHFQ22P1007  BHFQ22P1517  BHFQ22P1007  BHFQ22P1517
                                                                                                                     AIR   PURIFIER
 Extended level difference kit - Allows outdoor unit to be more than 50m
 above indoor units  Special order unit
 Central drain pan kit - Installs onto the underside of the outdoor unit and collects drain
 Kits  water from all bottom plate outlets into a single outlet. In cold areas should be heated by
 a field-supplied heater to prevent drain water from freezing in the drain pan.
 Heater tape kit - Optional electrical heater to guarantee trouble-free operation in
 extremely cold and humid climates (one per outdoor unit needed)  •  EKBPH012T7A  EKBPH020T7A  EKBPH012T7A  EKBPH012T7A EKBPH020T7A EKBPH012T7A EKBPH020T7A  EKBPH012T7A EKBPH020T7A
 BHGP26A1                                                                                                             HEATING
 Digital pressure gauge kit – displays current condensing and evaporating pressures in the   1 kit    1 kit    1 kit    1 kit    1 kit    1 kit
 system as Standard, or expansion valve positions and temperature sensor data in a special   •  •  •  per system  per system  •  •  •  •  per system  per system  •  •  per system  per system
 service mode. Connect to the outdoor unit PCB, for installation in the outdoor unit.
 External control adapter for outdoor unit - Allows to activate Low Noise Operation and
 three levels of demand control, limiting power consumption via external dry contacts.   DTA104A53/61/62  DTA104A53/61/62
 For installation into an indoor unit: exact adapter type depends on type of indoor unit.
                                  For installation into an indoor unit: exact adapter type depends on type of indoor unit.
 Connects to the F1/F2 communication line and requires power supply from an indoor unit,   For 14-20 HP the demand PCB mouting plate is required. See Options & Accessories of indoor units  For 14-20 HP the demand PCB mouting plate is required. See Options & Accessories of indoor units
 BSVQ box, or VRV-WIII outdoor unit.
 Adapters KRC19-26A  •  •  •  •  •  per system  per system  •  •  per system  per system  •  •   per system  per system  SPLIT
                                                                                                           1 kit
                                    1 kit
                                                                           1 kit
                                                                                                   1 kit
                                            1 kit
                                                                   1 kit
 Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or one
 BS-box of a Heat Recovery system between cooling, heating and fan only. Connects to the
 A-B-C terminals of the outdoor unit / BS-box.
 Cool/heat selector PCB (required to connect KRC19-26A)  Standard on unit  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81
                                 (1 kit per system) (1 kit per system)  (1 kit per system) (1 kit per system)  (1 kit per system) (1 kit per system)
 KKSA26A560*                        1 kit    1 kit                 1 kit    1 kit
 Cool/heat selector PCB mounting plate (only required when cool/heat selector PCB and   •  •  per system  per system  •  per system  per system
 Heater tape kit are combined)
 KJB111A  •  •  •    •       •      1 kit    1 kit    •     •      1 kit    1 kit    •      •      1 kit    1 kit
 Installation box for remote cool/heat selector KRC19-26A  per system  per system  per system  per system  per system  per system  SKY AIR
 EKCHSC - Cool/heat selector cable
 EKPCCAB4  •  •  •  •  •  •  •  •  •  •  •  •       •       •       •       •       •       •       •       •
 Others VRV configurator  •  •                              •
 KKSB26B1*
 Demand PCB mounting plate. Needed to mount Demand PCB for one or more outdoor units.
 DTA109A51
 DIII-net expander adapter  •  •  •  •  •  •  •  •  •  •  •  •  •   •       •
 BPMKS967A2/A3
 Branch provider (for connection of 2/3 RA indoor units)  •  •  •  •                •       •
 EKDK04                                                                                                               VRV
 Drain plug kit
 *Note: blue cells contain preliminary data
                                                               VRV IV i-series
 VRV IV S-series                                                 SB.RKXYQ
 RXYSCQ-TV1  RXYSQ4-6TV9  RXYSQ4-6TY9  RXYSQ8-12TY1  RDXYQ5  RDXYQ8         RKXYQ5                RKXYQ8
 Multi-module connection kit (obligatory) - Connects multiple modules into a single                                  VENTILATION & BID-  DLE AIR CURTAINS
 refrigerant system
 Extended level difference kit - Allows outdoor unit to be more than 50m
 above indoor units
 Central drain pan kit - Installs onto the underside of the outdoor unit and collects drain
 Kits  water from all bottom plate outlets into a single outlet. In cold areas should be heated by
 a field-supplied heater to prevent drain water from freezing in the drain pan.
 Heater tape kit - Optional electrical heater to guarantee trouble-free operation in   EKDPH1RDX  EKDPH1RDX           MARINE TYPES
 extremely cold and humid climates (one per outdoor unit needed)
 BHGP26A1
 Digital pressure gauge kit – displays current condensing and evaporating pressures in the
 system as Standard, or expansion valve positions and temperature sensor data in a special
 service mode. Connect to the outdoor unit PCB, for installation in the outdoor unit.
 External control adapter for outdoor unit - Allows to activate Low Noise Operation and
 DTA104A53/61/62
                                                    DTA104A53/61/62
 three levels of demand control, limiting power consumption via external dry contacts.   For installation into an indoor unit: exact adapter type depends on type of indoor unit.    For installation into an indoor unit: exact adapter type depends on type of indoor unit.
 Connects to the F1/F2 communication line and requires power supply from an indoor unit,   See Options & Accessories of indoor units  See Options & Accessories of indoor units  CHILLERS
 BSVQ box, or VRV-WIII outdoor unit.
 KRC19-26A
 Adapters  Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or one   •  •  •  •
 BS-box of a Heat Recovery system between cooling, heating and fan only. Connects to the
 A-B-C terminals of the outdoor unit / BS-box.
 Cool/heat selector PCB (Required to connect KRC19-26A)  EBRP2B                                   BRP2A81
 KKSA26A560*
 Cool/heat selector PCB mounting plate (only required when cool/heat selector PCB and
 Heater tape kit are combined)                                                                                        FAN COIL UNITS
 KJB111A
 Installation box for remote cool/heat selector KRC19-26A  •  •               •                     •
 EKCHSC - Cool/heat selector cable (Required to connect KRC19-26A)  •
 EKPCCAB4  •  •  •  •                                                         •                     •
 Others VRV configurator
 KKSB26B1*
 Demand PCB mounting plate. Needed to mount Demand PCB for one or more outdoor units.
 DTA109A51
 DIII-net expander adapter                                                                                           AIR HANDLING   UNITS
 BPMKS967A2/A3
 Branch provider (for connection of 2/3 RA indoor units)  •  •  •  •
 EKDK04  •  •
 Drain plug kit