Page 470 - General Catalogue
P. 470

Options & accessories -        outdoor
                                                               VRV S-series               VRV IV Heat Recovery                         VRV IV with continuous heating          VRV IV without continuous heating  VRV IV C+series
                                                                                                       2-module   3-module                               2-module   3-module             2-module   3-module            2-module   3-module
                                                              RXYSA-AV1/AY1  REYQ 8~12  REYQ 14~20  REMQ5  systems  systems  RYYQ8-12  RYYQ14-20  RYMQ8-12  RYMQ14-20  systems  systems  RXYQ8-12  RXYQ14-20  systems  systems  RXYLQ  RXMLQ  systems  systems
          Multi-module connection kit (obligatory) - Connects multiple modules into a single
          refrigerant system                                                                           BHFQ23P907  BHFQ23P1357                          BHFQ22P1007 BHFQ22P1517         BHFQ22P1007  BHFQ22P1517        BHFQ22P1007  BHFQ22P1517
          Extended level difference kit - Allows outdoor unit to be more than 50m
          above indoor units                                                               Special order unit
          Central drain pan kit - Installs onto the underside of the outdoor unit and collects drain
         Kits  water from all bottom plate outlets into a single outlet. In cold areas should be heated by
          a field-supplied heater to prevent drain water from freezing in the drain pan.
          Heater tape kit - Optional electrical heater to guarantee trouble-free operation in
          extremely cold and humid climates (one per outdoor unit needed)  •  EKBPH012T7A  EKBPH020T7A  EKBPH012T7A      EKBPH012T7A EKBPH020T7A EKBPH012T7A EKBPH020T7A  EKBPH012T7A EKBPH020T7A
          BHGP26A1
          Digital pressure gauge kit – displays current condensing and evaporating pressures in the      1 kit    1 kit                                    1 kit    1 kit                 1 kit    1 kit
          system as Standard, or expansion valve positions and temperature sensor data in a special   •  •  •  per system  per system  •  •  •      •    per system  per system  •  •    per system  per system
          service mode. Connect to the outdoor unit PCB, for installation in the outdoor unit.
          External control adapter for outdoor unit - Allows to activate Low Noise Operation and
          three levels of demand control, limiting power consumption via external dry contacts.   DTA104A53/61/62                                                          DTA104A53/61/62
                                                                     For installation into an indoor unit: exact adapter type depends on type of indoor unit.
                                                                                                                                                         For installation into an indoor unit: exact adapter type depends on type of indoor unit.
          Connects to the F1/F2 communication line and requires power supply from an indoor unit,   For 14-20 HP the demand PCB mouting plate is required. See Options & Accessories of indoor units  For 14-20 HP the demand PCB mouting plate is required. See Options & Accessories of indoor units
          BSVQ box, or VRV-WIII outdoor unit.
         Adapters KRC19-26A                                       •                                                         •       •       •       •    per system  per system  •  •    per system  per system  •  •   per system  per system
                                                                                                                                                                   1 kit
                                                                                                                                                                                                  1 kit
                                                                                                                                                                                          1 kit
                                                                                                                                                                                                                                  1 kit
                                                                                                                                                                                                                          1 kit
                                                                                                                                                           1 kit
          Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or one
          BS-box of a Heat Recovery system between cooling, heating and fan only. Connects to the
          A-B-C terminals of the outdoor unit / BS-box.
          Cool/heat selector PCB (required to connect KRC19-26A)  Standard on unit                                        BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81  BRP2A81
                                                                                                                                                        (1 kit per system) (1 kit per system)  (1 kit per system) (1 kit per system)  (1 kit per system) (1 kit per system)
          KKSA26A560*                                                                                                                                      1 kit    1 kit                 1 kit    1 kit
          Cool/heat selector PCB mounting plate (only required when cool/heat selector PCB and                                      •               •    per system  per system    •     per system  per system
          Heater tape kit are combined)
          KJB111A                                                 •                                                         •       •       •       •      1 kit    1 kit    •     •      1 kit    1 kit    •      •      1 kit    1 kit
          Installation box for remote cool/heat selector KRC19-26A                                                                                       per system  per system          per system  per system         per system  per system
          EKCHSC - Cool/heat selector cable
          EKPCCAB4                                                •         •         •         •        •         •        •       •       •       •       •      •       •       •       •       •       •       •       •       •
         Others VRV configurator                                                                                                    •               •                              •
          KKSB26B1*
          Demand PCB mounting plate. Needed to mount Demand PCB for one or more outdoor units.
          DTA109A51
          DIII-net expander adapter                                         •         •         •        •         •        •       •       •       •       •      •       •       •       •       •
          BPMKS967A2/A3
          Branch provider (for connection of 2/3 RA indoor units)                                                           •       •                                      •       •                       •       •
          EKDK04
          Drain plug kit
             *Note: blue cells contain preliminary data
                                                                                                                                                                                      VRV IV i-series
                                                                                                  VRV IV S-series                                                                       SB.RKXYQ
                                                                    RXYSCQ-TV1         RXYSQ4-6TV9        RXYSQ4-6TY9          RXYSQ8-12TY1            RDXYQ5                RDXYQ8                RKXYQ5                RKXYQ8
          Multi-module connection kit (obligatory) - Connects multiple modules into a single
          refrigerant system
          Extended level difference kit - Allows outdoor unit to be more than 50m
          above indoor units
          Central drain pan kit - Installs onto the underside of the outdoor unit and collects drain
         Kits  water from all bottom plate outlets into a single outlet. In cold areas should be heated by
          a field-supplied heater to prevent drain water from freezing in the drain pan.
          Heater tape kit - Optional electrical heater to guarantee trouble-free operation in                                                         EKDPH1RDX              EKDPH1RDX
          extremely cold and humid climates (one per outdoor unit needed)
          BHGP26A1
          Digital pressure gauge kit – displays current condensing and evaporating pressures in the
          system as Standard, or expansion valve positions and temperature sensor data in a special
          service mode. Connect to the outdoor unit PCB, for installation in the outdoor unit.
          External control adapter for outdoor unit - Allows to activate Low Noise Operation and
                                                                                       DTA104A53/61/62
                                                                                                                                                                           DTA104A53/61/62
          three levels of demand control, limiting power consumption via external dry contacts.   For installation into an indoor unit: exact adapter type depends on type of indoor unit.    For installation into an indoor unit: exact adapter type depends on type of indoor unit.
          Connects to the F1/F2 communication line and requires power supply from an indoor unit,   See Options & Accessories of indoor units                        See Options & Accessories of indoor units
          BSVQ box, or VRV-WIII outdoor unit.
          KRC19-26A
         Adapters  Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or one   •    •                                                                                      •                     •
          BS-box of a Heat Recovery system between cooling, heating and fan only. Connects to the
          A-B-C terminals of the outdoor unit / BS-box.
          Cool/heat selector PCB (Required to connect KRC19-26A)                         EBRP2B                                                                                                                          BRP2A81
          KKSA26A560*
          Cool/heat selector PCB mounting plate (only required when cool/heat selector PCB and
          Heater tape kit are combined)
          KJB111A
          Installation box for remote cool/heat selector KRC19-26A                         •                  •                                                                                      •                     •
          EKCHSC - Cool/heat selector cable (Required to connect KRC19-26A)                                   •
          EKPCCAB4                                                     •                   •                  •                    •                                                                 •                     •
         Others VRV configurator
          KKSB26B1*
          Demand PCB mounting plate. Needed to mount Demand PCB for one or more outdoor units.
          DTA109A51
          DIII-net expander adapter
          BPMKS967A2/A3
          Branch provider (for connection of 2/3 RA indoor units)      •                   •                  •                    •
          EKDK04                                                                           •                  •
          Drain plug kit