Page 470 - General Catalogue
P. 470
Options & accessories - outdoor
VRV S-series VRV IV Heat Recovery VRV IV with continuous heating VRV IV without continuous heating VRV IV C+series
2-module 3-module 2-module 3-module 2-module 3-module 2-module 3-module
RXYSA-AV1/AY1 REYQ 8~12 REYQ 14~20 REMQ5 systems systems RYYQ8-12 RYYQ14-20 RYMQ8-12 RYMQ14-20 systems systems RXYQ8-12 RXYQ14-20 systems systems RXYLQ RXMLQ systems systems
Multi-module connection kit (obligatory) - Connects multiple modules into a single
refrigerant system BHFQ23P907 BHFQ23P1357 BHFQ22P1007 BHFQ22P1517 BHFQ22P1007 BHFQ22P1517 BHFQ22P1007 BHFQ22P1517
Extended level difference kit - Allows outdoor unit to be more than 50m
above indoor units Special order unit
Central drain pan kit - Installs onto the underside of the outdoor unit and collects drain
Kits water from all bottom plate outlets into a single outlet. In cold areas should be heated by
a field-supplied heater to prevent drain water from freezing in the drain pan.
Heater tape kit - Optional electrical heater to guarantee trouble-free operation in
extremely cold and humid climates (one per outdoor unit needed) • EKBPH012T7A EKBPH020T7A EKBPH012T7A EKBPH012T7A EKBPH020T7A EKBPH012T7A EKBPH020T7A EKBPH012T7A EKBPH020T7A
BHGP26A1
Digital pressure gauge kit – displays current condensing and evaporating pressures in the 1 kit 1 kit 1 kit 1 kit 1 kit 1 kit
system as Standard, or expansion valve positions and temperature sensor data in a special • • • per system per system • • • • per system per system • • per system per system
service mode. Connect to the outdoor unit PCB, for installation in the outdoor unit.
External control adapter for outdoor unit - Allows to activate Low Noise Operation and
three levels of demand control, limiting power consumption via external dry contacts. DTA104A53/61/62 DTA104A53/61/62
For installation into an indoor unit: exact adapter type depends on type of indoor unit.
For installation into an indoor unit: exact adapter type depends on type of indoor unit.
Connects to the F1/F2 communication line and requires power supply from an indoor unit, For 14-20 HP the demand PCB mouting plate is required. See Options & Accessories of indoor units For 14-20 HP the demand PCB mouting plate is required. See Options & Accessories of indoor units
BSVQ box, or VRV-WIII outdoor unit.
Adapters KRC19-26A • • • • • per system per system • • per system per system • • per system per system
1 kit
1 kit
1 kit
1 kit
1 kit
1 kit
Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or one
BS-box of a Heat Recovery system between cooling, heating and fan only. Connects to the
A-B-C terminals of the outdoor unit / BS-box.
Cool/heat selector PCB (required to connect KRC19-26A) Standard on unit BRP2A81 BRP2A81 BRP2A81 BRP2A81 BRP2A81 BRP2A81 BRP2A81 BRP2A81 BRP2A81 BRP2A81 BRP2A81 BRP2A81 BRP2A81 BRP2A81
(1 kit per system) (1 kit per system) (1 kit per system) (1 kit per system) (1 kit per system) (1 kit per system)
KKSA26A560* 1 kit 1 kit 1 kit 1 kit
Cool/heat selector PCB mounting plate (only required when cool/heat selector PCB and • • per system per system • per system per system
Heater tape kit are combined)
KJB111A • • • • • 1 kit 1 kit • • 1 kit 1 kit • • 1 kit 1 kit
Installation box for remote cool/heat selector KRC19-26A per system per system per system per system per system per system
EKCHSC - Cool/heat selector cable
EKPCCAB4 • • • • • • • • • • • • • • • • • • • •
Others VRV configurator • • •
KKSB26B1*
Demand PCB mounting plate. Needed to mount Demand PCB for one or more outdoor units.
DTA109A51
DIII-net expander adapter • • • • • • • • • • • • • • •
BPMKS967A2/A3
Branch provider (for connection of 2/3 RA indoor units) • • • • • •
EKDK04
Drain plug kit
*Note: blue cells contain preliminary data
VRV IV i-series
VRV IV S-series SB.RKXYQ
RXYSCQ-TV1 RXYSQ4-6TV9 RXYSQ4-6TY9 RXYSQ8-12TY1 RDXYQ5 RDXYQ8 RKXYQ5 RKXYQ8
Multi-module connection kit (obligatory) - Connects multiple modules into a single
refrigerant system
Extended level difference kit - Allows outdoor unit to be more than 50m
above indoor units
Central drain pan kit - Installs onto the underside of the outdoor unit and collects drain
Kits water from all bottom plate outlets into a single outlet. In cold areas should be heated by
a field-supplied heater to prevent drain water from freezing in the drain pan.
Heater tape kit - Optional electrical heater to guarantee trouble-free operation in EKDPH1RDX EKDPH1RDX
extremely cold and humid climates (one per outdoor unit needed)
BHGP26A1
Digital pressure gauge kit – displays current condensing and evaporating pressures in the
system as Standard, or expansion valve positions and temperature sensor data in a special
service mode. Connect to the outdoor unit PCB, for installation in the outdoor unit.
External control adapter for outdoor unit - Allows to activate Low Noise Operation and
DTA104A53/61/62
DTA104A53/61/62
three levels of demand control, limiting power consumption via external dry contacts. For installation into an indoor unit: exact adapter type depends on type of indoor unit. For installation into an indoor unit: exact adapter type depends on type of indoor unit.
Connects to the F1/F2 communication line and requires power supply from an indoor unit, See Options & Accessories of indoor units See Options & Accessories of indoor units
BSVQ box, or VRV-WIII outdoor unit.
KRC19-26A
Adapters Mechanical cool/heat selector – allows to switch an entire Heat Pump system, or one • • • •
BS-box of a Heat Recovery system between cooling, heating and fan only. Connects to the
A-B-C terminals of the outdoor unit / BS-box.
Cool/heat selector PCB (Required to connect KRC19-26A) EBRP2B BRP2A81
KKSA26A560*
Cool/heat selector PCB mounting plate (only required when cool/heat selector PCB and
Heater tape kit are combined)
KJB111A
Installation box for remote cool/heat selector KRC19-26A • • • •
EKCHSC - Cool/heat selector cable (Required to connect KRC19-26A) •
EKPCCAB4 • • • • • •
Others VRV configurator
KKSB26B1*
Demand PCB mounting plate. Needed to mount Demand PCB for one or more outdoor units.
DTA109A51
DIII-net expander adapter
BPMKS967A2/A3
Branch provider (for connection of 2/3 RA indoor units) • • • •
EKDK04 • •
Drain plug kit
468