Page 427 - General Catalogue
P. 427

INTRODUCTION

          RXYSCQ-TV1

          VRV IV S-series compact

          heat pump
                                                                                                                     AIR   PURIFIER


          The most compact VRV

            › Compact & lightweight single fan design makes the unit almost
           unnoticeable
            › Covers all thermal needs of a building via a single point of contact:                    823mm          HEATING
           accurate temperature control, ventilation, air handling units and
           Biddle air cutains
            › Wide range of indoor units: either connect VRV or stylish indoor
           units such as Daikin Emura, Nexura ...
            › Incorporates VRV IV standards & technologies: Variable Refrigerant                                      SPLIT
           Temperature and full inverter compressors
            › Possibility to limit peak power consumption between 30 and 80%,
           for example during periods with high power demand
            › Night quiet mode reduces sound pressure with up to 8dBa         RXYSCQ-TV1
            › Contains all standard VRV features                                                      Only
                                                                                                  823mm               SKY AIR
                                                                                                       high!
                                                                  ErP 2021
                                                                  COMPLIANT
                                                                Already fully compliant
                                                                to LOT 21 - Tier 2
                                                              Published data with                                     VRV
                                                              real-life indoor units
          Connectable stylish indoor units
                                                     15 CLASS  20 CLASS  25 CLASS  35 CLASS  42 CLASS  50 CLASS  60 CLASS  71 CLASS
          Round flow cassette                  FCAG-B
          Fully flat cassette                   FFA-A9
          Slim concealed ceiling unit          FDXM-F9
          Concealed ceiling unit with inverter driven fan  FBA-A(9)                                                  VENTILATION & BID-  DLE AIR CURTAINS
          Daikin Emura - Wall mounted unit  FTXJ-MW/MS
          Stylish - Wall mounted unit           FTXA-A
          Perfera - Wall mounted unit    CTXM-N / FTXM-N
          Ceiling suspended unit               FHA-A(9)
          Nexura - Floor standing unit         FVXG-K
          Floor standing unit                  FVXM-F
          Concealed floorstanding unit          FNA-A9                                                                MARINE TYPES

               Access all technical information on RXYSCQ-TV1
               at my.daikin.eu or click here                                                       NEW
          Outdoor unit                       RXYSCQ        4TV1                5TV1                 6TV1
          Capacity range                        HP          4                    5                   6                CHILLERS
          Cooling capacity  Prated,c            kW          12.1                14.0                15.5
          Heating capacity  Prated,h            kW          8.4                 9.7                 10.7
                      Max.  6°CWB               kW         14.2                 16.0                18.0
          Recommended combination                  3 x FXSQ25A2VEB + 1 x FXSQ32A2VEB  4 x FXSQ32A2VEB   2 x FXSQ32A2VEB + 2 x FXSQ40A2VEB
          ηs,c                                   %         322.8               303.4                281.3
          ηs,h                                   %         182.3                185.1               186.0
          SEER                                              8.1                 7.7                  7.1              FAN COIL UNITS
          SCOP                                              4.6                           4.7
          Maximum number of connectable indoor units                            64
          Indoor index   Min.                              50.0                 62.5                70.0
          connection  Nom.                                                       -
                      Max.                                 130.0                162.5               182.0
          Dimensions  Unit  HeightxWidthxDepth  mm                           823x940x460
          Weight      Unit                      kg                              89                                   AIR HANDLING   UNITS
          Sound power level Cooling  Nom.      dBA         68.0                 69.0                70.0
          Sound pressure level  Cooling  Nom.  dBA         51.0                 52.0                53.0
          Operation range  Cooling  Min.~Max.  °CDB                           -5.0~46.0
                      Heating  Min.~Max.       °CWB                           -20.0~15.5
          Refrigerant  Type/GWP                                              R-410A/2,087.5
                      Charge                  kg/TCO2Eq                        3.7/7.7
          Piping connections Liquid  OD        mm                               9.52                                  REFRIGERATION
                      Gas   OD                 mm                     15.9                          19.1
                      Total piping System  Actual  m                            300
                      length
          Power supply  Phase/Frequency/Voltage  Hz/V                        1~/50/220-240
          Current - 50Hz  Maximum fuse amps (MFA)  A                            32
                                                                                                                     CONTROL   SYSTEMS
          (1)Actual number of units depends on the indoor unit type (VRV DX indoor, RA DX indoor, etc.) and the connection ratio restriction for the system (being; 50% ≤ CR ≤130%).
                                                                                                             425