INTRODUCTION

          SB.RKXYQ-T(8)

          VRV IV heat pump for

          indoor installation
                                                                                                                     AIR   PURIFIER


          The invisible VRV

            › Unique VRV heat pump for indoor installation
                                                                                                                      HEATING






                                                                                                                      SPLIT
            › Unrivalled flexibility because the unit is split up into two elements:
           the heat exchanger and the compressor                                         SB.RKXYQ5T8
                      Heat exchanger
                         unit
                                                                                                                      SKY AIR
                                                                › Covers all thermal needs of a building via a single point of contact:
                     Max. 70 m                                 accurate temperature control, ventilation, air handling units and
                                                               Biddle air cutains
                         Max. 30 m  Compressor unit can be above heat
           VRV Indoor            exchanger unit as well         › Lightweight units (max. 105kg) can be installed by two people
           units
                                                                › Unique V-shape heat exchanger results in compact dimensions
                                                               (h/e unit only 400mm high) allowing false ceiling installation,   VRV
                                                               while ensuring top efficiency
                    Compressor unit                             › Super efficient centrifugal fans (over 50%
            › Highly suited to densely populated areas thanks to the low   efficiency increase compared to sirocco fan)  ErP 2021
                                                                                                         COMPLIANT
           operation sound and seamless integration into surrounding     › Small footprint compressor unit (760 x 554 mm)
           architecture as only the grille is visible          maximizing useable floor space         Already fully compliant
            › Incorporates VRV IV standards & technologies: Variable Refrigerant     › Contains all standard VRV features  to LOT 21 - Tier 2  VENTILATION & BID-  DLE AIR CURTAINS
           Temperature, VRV configurator and full inverter compressors                              Published data with
                                                                                                    real-life indoor units
               Access all technical information on SB-RKXYQ-T      Access all technical information on SB-RKXYQ-T(8)
               at my.daikin.eu or click here                       at my.daikin.eu or click here
          System                           SB.RKXYQ             5T8                            8T                     MARINE TYPES
          System      Heat exchanger unit                     RDXYQ5T8                       RDXYQ8T
                      Compressor unit                         RKXYQ5T8                       RKXYQ8T
          Capacity range                        HP               5                              8
          Cooling capacity  Prated,c            kW               14.0                          22.4
          Heating capacity  Prated,h            kW               10.4                          12.9
                      Max.        6°CWB         kW               16.0                          25.0
          Recommended combination                           4 x FXSQ32A2VEB                4 x FXMQ50P7VEB
          ηs,c                                   %              200.1                          191.1                  CHILLERS
          ηs,h                                   %              149.3                          140.9
          SEER                                                   5.1                           4.9
          SCOP                                                   3.8                           3.6
          Maximum number of connectable indoor units             10                             17
          Indoor index   Min.                                   62.5                           100.0
          connection  Nom.                                                       -
                      Max.                                      162.5                          260.0                  FAN COIL UNITS
          Piping connections Liquid  OD        mm                                -
                      Gas         OD           mm                                -
                      Between Compressor   Liquid  OD  mm                       12.7
                      module (CM) and heat  Gas  OD  mm          19.1                          22.2
                      exchanger module (HM)
                      Between Compressor  Liquid  OD  mm                        9.52
                      module (CM) and   Gas  OD  mm              15.9                          19.1                  AIR HANDLING   UNITS
                      indoor units (IU)
                      Total piping length System  Actual  m      140                           300
                                                       Heat exchanger module - RDXYQ   Compressor module - RKXYQ
          Outdoor unit module                            5T8             8T            5T8             8T
          Dimensions  Unit        HeightxWidthxDepth  mm     397x1,456x1,044         701x600x554    701x760x554
          Weight      Unit                      kg       95             103             79             105
          Fan         Air flow rate  Cooling Nom.  m³/min  55           100                     -                     REFRIGERATION
          Sound power level Cooling  Nom.      dBA       77.0            81            60.0            64
          Sound pressure level  Cooling  Nom.  dBA       47.0            54             47.0           48
          Refrigerant  Type/GWP                                R-410A/-                     R-410A/2,087.5
                      Charge                  kg/TCO2Eq          -/-                  2.00/4.20      4.00/8.35
          Power supply  Phase/Frequency/Voltage  Hz/V        1N~/50/220-240                 3N~/50/380-415
          Current - 50Hz  Maximum fuse amps (MFA)  A             10                     16             20
                                                                                                                     CONTROL   SYSTEMS