Page 422 - General Catalogue
P. 422

REYQ-U

          VRV IV+ heat recovery



          Best efficiency & comfort solution

            › Fully integrated solution with heat recovery for maximum     › Free combination of outdoor units to meet installation space or
           efficiency with COPs of up to 8 !                   efficiency requirements
            › Covers all thermal needs of a building via a single point of contact:     › Wide piping flexibility: 30m indoor height difference, maximum
           accurate temperature control, ventilation, hot water, air handling   piping length: 190m, total piping length: 1,000m
           units and Biddle air curtains                        › Possibility to extend the operation range in cooling down to -20°C
            › „Free“ heating and hot water production provided by transferring   for technical cooling operation such as server rooms
           heat from areas requiring cooling to areas requiring heating or hot     › Contains all standard VRV features
           water
            › The perfect personal comfort for guests/tenants via simultaneous
           cooling and heating
            › Incorporates VRV IV standards & technologies: Variable Refrigerant   CERTIFIED
           Temperature, continuous heating, VRV configurator, 7 segment        RECLAIMED
           display and full inverter compressors, 4-side heat exchanger,
           refrigerant cooled PCB, new DC fan motor
            › Outdoor unit display for quick on-site settings and easy read out                    ErP 2021
           of errors together with the indication of service parameters for                         COMPLIANT
           checking basic functions.                                     ALLOCATION  REFRIGERANT
                                                                                                Already fully compliant
                                                                                                  to LOT 21 - Tier 2
                                                                  By choosing this product with Certified   Published data with
                                                                 Reclaimed Refrigerant Allocation you support   real-life indoor units
                                                                      the re-use of refrigerant
               Access all technical information on REYQ-U
               at my.daikin.eu or click here

          Outdoor unit                        REYQ    8U      10U      12U      14U      16U     18U      20U
          Capacity range                        HP    8        10       12      14       16       18      20
          Cooling capacity  Prated,c            kW    22.4    28.0     33.5     40.0     45.0    50.4     52.0
          Heating capacity  Prated,h            kW    13.7    16.0     18.4     20.6     23.2    27.9     31.0
                      Max.  6°CWB               kW    25.0    31.5     37.5     45.0    50.0     56.5     63.0
          ηs,c                                   %   286.1    264.8    257.0   255.8    243.1    250.6    246.7
          ηs,h                                   %   165.1    169.7    183.8   168.3    167.5    172.5    162.7
          SEER                                        7.2      6.7          6.5          6.2      6.3     6.2
          SCOP                                        4.2      4.3     4.7          4.3           4.4     4.1
          Maximum number of connectable indoor units                            64
          Indoor index   Min.                        100.0    125.0    150.0    175.0   200.0    225.0    250.0
          connection  Nom.                                                       -
                      Max.                           260.0    325.0    390.0   455.0    520.0    585.0    650.0
          Dimensions  Unit  HeightxWidthxDepth  mm         1,685x930x765                 1,685x1,240x765
          Weight      Unit                      kg            230                   314               317
          Sound power level Cooling  Nom.      dBA    78.0    79.1     83.4     80.9    85.6     83.8     87.9
          Sound pressure level  Cooling  Nom.  dBA        57.0         61.0     60.0    63.0     62.0     65.0
          Operation range  Cooling  Min.~Max.  °CDB                           -5.0~43.0
                      Heating  Min.~Max.       °CWB                           -20.0~15.5
          Refrigerant  Type/GWP                                              R-410A/2,087.5
                      Charge                 kg/TCO2Eq  9.7/20.2  9.8/20.5  9.9/20.7        11.8/24.6
          Piping connections Liquid  OD        mm         952                   127                   159
                      Gas   OD                 mm     19.1    22.2                      28.6
                      HP/LP gas OD             mm     15.9         19.1                  22.2             28.6
                      Total piping System  Actual  m                           1,000
                      length
          Power supply  Phase/Frequency/Voltage  Hz/V                       3N~/50/380-415
          Current - 50Hz  Maximum fuse amps (MFA)  A  20       25           32               40           50
          Outdoor unit System + Module        REYQ  10U   13U  16U   18U  20U   22U  24U   26U  28U   30U   32U
          System      Outdoor unit module 1          REMQ5U        REYQ8U     REYQ10U REYQ8U   REYQ12U    REYQ16U
                      Outdoor unit module 2        REMQ5U  REYQ8U  REYQ10U  REYQ12U  REYQ16U REYQ14U REYQ16U REYQ18U REYQ16U
          Capacity range                        HP   10   13    16   18    20   22    24   26    28    30   32
          Cooling capacity  Prated,c            kW  28.0  36.4  44.8  50.4  55.9  61.5  67.4  73.5  78.5  83.9  90.0
          Heating capacity  Prated,h            kW  16.0  21.7  23.2  27.9  31.0  34.4  36.9  37.1  39.7  44.4  46.4
                      Max.  6°CWB               kW  32.0  41.0  50.0  56.5  62.5  69.0  75.0  82.5  87.5  94.0  100.0
          ηs,c                                   %  275.1  301.3  288.6  272.9  266.0  260.4  257.7  257.5  251.9  266.8  243.1
          ηs,h                                   %  158.8  160.6  168.2  167.9  175.7  178.5  167.6  175.5  174.8  179.4  169.1
          SEER                                      7.0   7.6   7.3  6.9   6.7  6.6     6.5      6.4  6.7   6.2
          SCOP                                      4.0   4.1     4.3        4.5      4.3  4.5   4.4  4.6   4.3
          Maximum number of connectable indoor units                            64
          Indoor index   Min.                       125.0  163.0  200.0  225.0  250.0  275.0  300.0  325.0  350.0  375.0  400.0
          connection  Nom.                                                       -
                      Max.                          325.0  423.0  520.0  585.0  650.0  715.0  780.0  845.0  910.0  975.0  1,040.0
          Piping connections Liquid  OD        mm   952      127             159                    191
                      Gas   OD                 mm   22.2             28.6                       34.9
                      HP/LP gas OD             mm      19.1       22.2                     28.6
                      Total piping System  Actual  m           500                           1,000
                      length
          Power supply  Phase/Frequency/Voltage  Hz/V                       3N~/50/380-415
          Current - 50Hz  Maximum fuse amps (MFA)  A      40            50               63              80