Page 417 - General Catalogue
P. 417
INTRODUCTION
Outdoor units
VRV indoor units Residential indoor units LT Hydrobox HXY-A HT Hydrobox HXHD-A HRV units VAM-, VKM- AHU connection EKEXV- + EKEQMCBA AHU connection EKEXV- + EKEQFCBA Air curtains CYV-DK- AIR PURIFIER
Capacity (HP)
Model Best efficiency & comfort solution Product name 4 5 6 8 10 12 13 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 Description / Combination O O Remarks
UNIQUE
+
VRV IV Heat Recovery REYQ-T
› Standard total system connection ratio limit: 50 ~ 130%
Air cooled - heat recovery VRV IV heat recovery › Covers all thermal needs of a building via a single point of contact: accurate REYQ-U with only VRV indoor units › Max 32 indoor units, even on 16HP and larger systems HEATING
› Fully integrated solution with heat recovery for maximum efficiency
temperature control, ventilation, hot water, air handling units and Biddle air curtains
with LT/HT Hydroboxes
› “Free” heating and hot water through heat recovery
› Total system connection ratio with HT hydroboxes up to 200% possible
› The perfect personal comfort for guests/tenants via
HRV units VAM-, VKM-
simultaneous cooling and heating
› Dedicated systems (with only ventilation units) not allowed –
› Incorporates VRV IV standards & technologies such as
a mix with standard VRV indoor units is allways neccessary
AHU connection EKEXV + EKEQMCBA
Variable Refrigerant temperature and continuous heating
› Allows technical cooling
› Widest range of BS boxes on the market
+
VRV IV Heat Pump RYYQ-T(8) / RXYQ-T(9) O › Standard total system connection ratio limit: 50 ~ 130%
Daikin’s optimum solution with top comfort Biddle air curtain CYV-DK- › Total system connection ratio with AHU is 50 ~ 110% SPLIT
VRV IV heat pump with continuous heating › Covers all thermal needs of a building via a single point of contact: accurate RYYQ-U with residential indoor units › Only single-module systems (RYYQ 8~20 T / RXYQ 8~20 T)
› Continuous heating during defrost
with only VRV indoor units
› 200% total system connection ratio possible under special circumstances
temperature control, ventilation, hot water, air handling units and Biddle air curtains
› Connectable to stylish indoor units (Daikin Emura, Nexura)
› Max 32 indoor units, even on 16HP, 18HP and 20HP systems
› Connection ratio: 80 ~ 130%
› Incorporates VRV IV standards & technologies such as Variable Refrigerant
› Max 32 indoor units, even on 16HP and larger systems
temperature and continuous heating
with LT Hydroboxes
› Contact Daikin in case of multi-module systems (>20HP)
VRV IV heat pump without continuous heating Daikin’s solution for comfort & low energy consumption RXYQ-U HRV units VAM-, VKM- › Total system connection ratio with AHU is 50 ~ 110% SKY AIR
› Covers all thermal needs of a building via a single point of contact:
AHU connection EKEXV + EKEQMCBA
accurate temperature control, ventilation, hot water, air handling units
and Biddle air curtains
AHU connection EKEXV + EKEQFCBA
› Connectable to stylish indoor units (Daikin Emura, Nexura)
› Incorporates VRV IV standards & technologies such as
Variable Refrigerant temperature
NEW The most compact VRV Biddle air curtain CYV-DK-
› Compact and lightweight single fan design saves space and is easy to install
RXYSCQ-TV1
VRVIV-S series Compact › Covers all thermal needs of a building via a single point of contact: accurate Compact NEW VRV IV-S RXYSQ-/RXYSCQ- O O O › Standard total system connection ratio limit: 50 ~ 130% VRV
temperature control, ventilation, air handling units and Biddle air curtains
Air cooled - heat pump UNIQUE Space saving solution without compromising on efficiency RXYSQT8V/ T8V with VRV indoor units only
› Either connect VRV of stylish indoor units (Daikin Emura, Nexura)
› Incorporates VRV IV standards & technologies such as Variable Refrigerant
temperature
› Space saving trunk design for flexible installation
› Covers all thermal needs of a building via a single point of contact:
VRVIV-S
series
accurate temperature control, ventilation, air handling units and
Biddle air curtains
TY1
› Either connect VRV of stylish indoor units (Daikin Emura, Nexura)
› Incorporates VRV IV standards & technologies such as Variable T8Y/TY1 T8Y/ with residential indoor units only › With residential indoor: connection ratio limit: 80 ~ 130% VENTILATION & BID- DLE AIR CURTAINS
Refrigerant temperature
UNIQUE The invisible VRV
› Unique VRV heat pump for indoor installation
› Total flexibility for any shop location and building type as the outdoor unit is
VRV IVheat pump for indoor installation › Incorporates VRV IV standards & technologies such as Variable Refrigerant SB.RKXYQ-T(8) VRV IV i series SB.RKXYQ-T(8) O O O O › Standard total system connection MARINE TYPES
invisible and split up in 2 parts
ratio limit: 50 ~ 130%
temperature
› Covers all thermal needs of a building via a single point of contact: accurate
temperature control, ventilation and Biddle air curtains
VRV IV-C series RXYLQ-T O › Standard total system connection ratio limit: 70 ~ 130%
+
VRV IV heat pump, optimised for cold climates › Suitable for single source heating RXYLQ-T with residential indoor units only › With residential indoor: connection ratio limit: 80 ~ 130% CHILLERS
Where heating is priority without compromising on efficiency
with VRV indoor units only
› Extended operation range down to -25°C in heating
› Stable heating capacity without any capacity loss down to -15°C
with LT hydroboxes
› Max. 32 indoor units, contact Daikin in case of multi-module systems (> 14HP)
› Very economical solution as a smaller outdoor unit model can be used
AHU connection EKEXV + EKEQMCBA
compared to the standard series
AHU connection EKEXV + EKEQFCBA › Total system connection ratio is 70~110%
› With AHU only connection ration is 90~110%
Quick & quality replacement for R-22 and R-407C systems
heat recovery › Cost-effective and fast replacement through re-use of exisiting piping RQCEQ-P3 VRV III-Q series Replacement H/R O O O O O O › Standard total system connection
+
› Drastically improve your comfort, efficiency and reliability
RQCEQ-P3
ratio limit: 50 ~ 130%
› No interuption of daily business while replacing your system
Replacement heat pump Quick & quality replacement for R-22 and R-407C systems RXYQQ-U VRV IV-Q Replacement H/P O O O O › Standard total system connection FAN COIL UNITS
› Replace Daikin and other manufacturers systems safely
› Cost-effective and fast replacement through re-use of exisiting piping
› Drastically improve your comfort, efficiency and reliability
› No interuption of daily business while replacing your system
› Replace Daikin and other manufacturers systems safely
› Incorporates VRV IV standards & technologies such as
Variable Refrigerant temperature RXYQQ-T ratio limit: 50 ~ 130%
+
Ideal for high rise buildings, using water as heat source VRV IV-W series Water-cooled VRV AIR HANDLING UNITS
› Reduced CO2 emissions thanks to the use of geothermal energy as a renewable energy source RWEYQ-T9 O › Standard total system connection ratio limit: 50 ~ 130%
Water cooled Water cooled VRV IV › Compact & lightweight design can be stacked for maximum space saving RWEYQ-T9* with split indoor units › Only single-module systems (RWEYQ8-14T9)
› No need for an external heating or cooling source when used in geothermal mode
with VRV indoor units
› Incorporates VRV IV standards & technologies such as Variable Refrigerant temperature
› Max 32 indoor units
› Connection ratio: 80 ~ 130%
› Variable Water Flow control option increases flexibility and control
› only in heat pump version
› Mixed connection of HT hydroboxes and VRV indoor units
REFRIGERATION
› Either connect VRV of stylish indoor units (Daikin Emura, Nexura with HT hydrobox
› 2 analogue input signals allowing external control AHU connection › Total system connection ratio with AHU + X indoor is 50 ~ 110%
› Total system connection ration with AHU only is 90~ 110%
... connection of indoor unit possible, but not neccessarily simultaneously with other allowed indoor units ... connection of indoor unit possible, but not neccessarily simultaneously with other allowed indoor units
CONTROL SYSTEMS
... connection of indoor unit possible even simultaneously with other checked units in the same row ... connection of indoor unit possible even simultaneously with other checked units in the same row
O O ... connection of indoor not possible on this outdoor unit system ... connection of indoor not possible on this outdoor unit system 415