Page 41 - General Catalogue
P. 41
INTRODUCTION
EHVX-D3V(G)/D6V(G)/D9W(G) + ERGA-DV3
Daikin Altherma 3 R F
Floor standing air to water heat pump for heating,
cooling and hot water; ideal for low energy houses AIR PURIFIER
› A combined stainless steel domestic hot water tank of 180 or 230L
and heat pump for easy installation
› Inclusion of all hydraulic components means no third party
components are required HEATING
› PCB board and hydraulic components are located in the front
for easy access
› Small installation footprint of 595 x 600 mm
› Integrated back-up heater choice of 3, 6, 9 kW EHVX-D6V EHVX-D6VG
› Outdoor unit extracts heat from the outdoor air, even at -25°C
SPLIT
ERGA-DV BRC1HHDK
SKY AIR
011-1W0218 222 +++ +
011-1W0245, 247 A A 65°C
011-1W0249 251
A ++ A
04S18D3V(G)/ 04S23D3V(G)/ 08S18D6V(G)/ 08S23D6V(G)/ 08S18D6V(G)/ 08S23D6V(G)/
Efficiency data EHVX + ERGA A + B
D6V(G) + 04DV D6V(G) + 04DV D9W(G) + 06DV D9W(G) + 06DV D9W(G) + 08DV D9W(G) + 08DV
Heating capacity Nom. kW 4.30 (1) / 4.60 (2) 6.00 (1) / 5.90 (2) 7.50 (1) / 7.80 (2) VRV
4.86 (1) / 4.52 (2) A
C
Power input Heating Nom. kW 0,850 (1) / 1.26 (2) 1.24 (1) / 1.69 (2) 1.63 (1) / 2.23 (2)
Cooling capacity Nom. kW 5.96 (1) / 5.09 (2) 6.25 (1) / 5.44 (2)
Power input Cooling Nom. kW 0,940 (1) / 1.36 (2) 1.06 (1) / 1.55 (2) 1.16 (1) / 1.73 (2)
D
COP 5.10 (1) / 3.65 (2) B 4.85 (1) / 3.50 (2) 4.60 (1) / 3.50 (2)
EER 5.17 (1) / 3.32 (2) 5.61 (1) / 3.28 (2) 5.40 (1) / 3.14 (2)
Space heating Average General SCOP 3.29 C 3.28 E 3.35
climate ŋs (Seasonal space % 129 128 131
water outlet heating efficiency) VENTILATION & BID- DLE AIR CURTAINS
55°C Seasonal space heating eff. class D A++ F
Average General SCOP 4.54 4.52 4.61
climate water ŋs (Seasonal space % 179 E 178 G 181
outlet 35°C heating efficiency)
Seasonal space heating eff. class A+++
Domestic hot water heating General Declared load profile L XL F L XL L XL
Average ŋwh (water heating efficiency) % 127 125 134 133 125 133 125 133 MARINE TYPES
climate Water heating energy efficiency class G A+
04S18D3V(G)/ 04S23D3V(G)/ 08S18D6V(G)/ 08S23D6V(G)/ 08S18D6V(G)/ 08S23D6V(G)/
Indoor Unit EHVX
D6V(G) D6V(G) D9W(G) D9W(G) D9W(G) D9W(G)
Casing Colour White + Black
Material Resin / Sheet metal
Dimensions Unit HeightxWidthxDepth mm 1,650x595x625 1,850x595x625 1,650x595x625 1,850x595x625 1,650x595x625 1,850x595x625
Weight Unit kg 131 139 131 139 131 139
Tank Water volume l 180 230 180 230 180 230 CHILLERS
Maximum water temperature °C 70
Maximum water pressure bar 10
Corrosion protection Pickling
Operation range Heating Ambient Min.~Max. °C 5~30
Water side Min.~Max. °C 15 ~65
Cooling Ambient Min.~Max. °CDB 5~35
Water side Min.~Max. °C 5~22
Domestic Ambient Min.~Max. °CDB 5~35 FAN COIL UNITS
hot water Water side Max. °C 70
Sound power level Nom. dBA 42
Sound pressure level Nom. dBA 28
Outdoor Unit ERGA 04DV 06DV 08DV
Dimensions Unit HeightxWidthxDepth mm 740x884x388
Weight Unit kg 58.5
Compressor Quantity 1 AIR HANDLING UNITS
Type Hermetically sealed swing compressor
Operation range Cooling Min.~Max. °CDB 10~43
Domestic hot water Min.~Max. °CDB -25~35
Refrigerant Type R-32
GWP 675.0
Charge kg 1.50
Charge TCO2Eq 1.01
Control Expansion valve REFRIGERATION
Sound power level Heating Nom. dBA 58 60 62
Cooling Nom. dBA 61 62
Sound pressure Heating Nom. dBA 44 47 49
level Cooling Nom. dBA 48 49 50
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1N~/50/230
Current Recommended fuses A 25
(1) Cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) Cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) CONTROL SYSTEMS
39