EHVH-D6V(G)/D9W(G) + ERGA-DV3

          Daikin Altherma 3 R F

          Floor standing air to water heat pump for heating
          and hot water; ideal for low energy houses

            › A combined stainless steel domestic hot water tank of 180 or 230L
           and heat pump for easy installation
            › Inclusion of all hydraulic components means no third party
           components are required
            › PCB board and hydraulic components are located in the front
           for easy access
            › Small installation footprint of 595 x 600 mm
            › Integrated back-up heater choice of  6 or 9 kW         EHVH-D6V        EHVH-D6VG
            › Outdoor unit extracts heat from the outdoor air, even at -25°C





                                                                             ERGA-DV                 BRC1HHDW


             011-1W0218  222                                          +++             +
             011-1W0245, 247                                         A               A          65°C
             011-1W0249  251
                                                                     A ++            A
                                                   04S18D6V(G)+  04S23D6V(G) +  08S18D6V(G)/D9W(G)  08S23D6V(G)/D9W(G)  08S18D6V(G)/D9W(G)  08S23D6V(G)/D9W(G)
          Efficiency data                EHVH + ERGA                 A +             B
                                                    04DV  04DV     + 06DV      + 06DV      + 08DV       + 08DV
          Heating capacity  Nom.                kW  4.30 (1) / 4.60 (2)  6.00 (1) / 5.90 (2)   7.50 (1) / 7.80 (2)
          Power input  Heating  Nom.            kW  0.850 (1) / 1.26 (2)   A 1.24 (1) / 1.69 (2)   C  1.63 (1) / 2.23 (2)
          COP                                       5.10 (1) / 3.65 (2)  4.85 (1) / 3.50 (2)   4.60 (1) / 3.50 (2)
                                                                     B
          Space heating   Average   General  SCOP                   3.26             D            3.32
                      climate      ŋs (Seasonal space   %           127                           130
                      water outlet   heating efficiency)
                      55°C         Seasonal space heating eff. class   C        A++   E
                      Average   General  SCOP          4.48               4.47                    4.56
                                                                     D
                      climate      ŋs (Seasonal space   %           176              F            179
                      water outlet   heating efficiency)
                      35°C         Seasonal space heating eff. class   E       A+++   G
          Domestic hot water heating   General  Declared load profile  L  XL  L  XL          L           XL
                      Average   ŋwh (water heating efficiency)  %  125  133  125  133       125          133
                      climate  Water heating energy efficiency class   F        A+
                                                                     G
          Indoor Unit                         EHVH 04S18D6V(G) 04S23D6V(G) 08S18D6V(G)/D9W(G) 08S23D6V(G)/D9W(G) 08S18D6V(G)/D9W(G) 08S23D6V(G)/D9W(G)
          Casing      Colour                                                 White + Black
                      Material                                             Resin / Sheet metal
          Dimensions  Unit  HeightxWidthxDepth  mm 1,650x595x625 1,850x595x625  1,650x595x625  1,850x595x625  1,650x595x625  1,850x595x625
          Weight      Unit                      kg   131   139      131         139         131          139
          Tank        Water volume                l  180  230       180         230         180         230
                      Maximum water temperature  °C                             70
                      Maximum water pressure    bar                             10
                      Corrosion protection                                     Pickling
          Operation range  Heating  Ambient  Min.~Max.  °C                      5~30
                            Water side Min.~Max.  °C                           15 ~65
                      Domestic  Ambient  Min.~Max.  °CDB                        5~35
                      hot water Water side Max.  °C                             70
          Sound power level Nom.               dBA                              42
          Sound pressure level Nom.            dBA                              28
          Outdoor Unit                        ERGA     04DV              06DV                     08DV
          Dimensions  Unit         HeightxWidthxDepth  mm                    740x884x388
          Weight      Unit                      kg                              58.5
          Compressor  Quantity                                                   1
                      Type                                           Hermetically sealed swing compressor
          Operation range  Cooling  Min.~Max.  °CDB                            10~43
                      Domestic hot water  Min.~Max.  °CDB                      -25~35
          Refrigerant  Type                                                     R-32
                      GWP                                                      675.0
                      Charge                    kg                              1.50
                      Charge                  TCO2Eq                            1.01
                      Control                                               Expansion valve
          Sound power level Heating  Nom.      dBA      58                60                       62
                      Cooling      Nom.        dBA      61                            62
          Sound pressure   Heating  Nom.       dBA      44                47                       49
          level       Cooling      Nom.        dBA      48                49                       50
          Power supply  Name/Phase/Frequency/Voltage  Hz/V                   V3/1N~/50/230
          Current     Recommended fuses          A                              25
          (1) Cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) Cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
          38 38
   35   36   37   38   39   40   41   42   43   44   45