Page 139 - General Catalogue
P. 139
INTRODUCTION
EKHHP-A2V3 + ERWQ-AV3
Daikin Altherma R HW
Hot water in an efficient way
AIR PURIFIER
› Domestic hot water is heated almost immediately
› Combine it with solar heating for even better energy efficiency
› Easy installation: no water tank pressure and only limited pressure
in the heat exchanger
› Low maintenance: no anode means no scale and lime HEATING
deposits or corrosion
› Electrical back-up (2.5 kW) ensures hot water under all
circumstances. The 500L tank can also be equipped
with an external hydraulic back-up
SPLIT
EKHHP300AB2V3 ERWQ-AV3
A +++ SKY AIR
A + 55°C
A
B VRV
C
D
E VENTILATION & BID- DLE AIR CURTAINS
F
G
MARINE TYPES
Efficiency data EKHHP + ERWQ 300A2V3 + 02AV3 500A2V3 + 02AV3
Domestic hot General Declared load profile L XL
water heating Average ŋwh (water heating % 119 124 CHILLERS
climate efficiency)
Water heating energy efficiency A+
class
COP 4.30 (1)
Indoor Unit EKHHP 300A2V3 500A2V3
Casing Colour Traffic white (RAL9016) / Dark grey (RAL7011)
Dimensions Unit HeightxWidthxDepth mm 1772x595x615 1778x790x790 FAN COIL UNITS
Weight Unit kg 70 80
Tank Water volume l 294 477
Maximum water temperature °C 85
Operation range Domestic Ambient Min.~Max. °CDB 2~35
hot water Water side Min.~Max. °C 5~55
Refrigerant Type R-410A UNITS
Outdoor Unit ERWQ 02AV3 02AV3 AIR HANDLING
Dimensions Unit HeightxWidthxDepth mm 550x765x285
Weight Unit kg 35
Compressor Quantity 1
Type Hermetically sealed swing compressor
Operation range Domestic hot water Min.~Max. °CDB -15~35
Refrigerant Type R-410A REFRIGERATION
GWP 2,087.5
Charge kg 1.05
Charge TCO2Eq 2.2
Sound pressure Heating Nom. dBA 47
level Cooling Nom. dBA 47
Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230
(1) At 7°C ambient temperature (2) Contains fluorinated greenhouse gases CONTROL SYSTEMS
137