                                                                                    ЧЕРТЕЖИ RXYSCQ-TV1 НА MY.DAIKIN.EU
          Подробные технические чертежи
          RXYSCQ-TV1



          RXYSCQ-TV1
                                                                2  Series installation
           Obstacle above, too                                                                 500 or less
            1  Stand-alone installation                         The relations between H, A and L are
                                            500 or less         as follows.                                   1000 or more
             The relations between H, A and L are   1000 or more
             as follows.
                                                                       Set the stand as:
                                                                Close the bottom of the installation frame
                    Set the stand as:                           to prevent the discharged air from being   250 or more
             Close the bottom of the installation               bypassed.                                1000 or more
             frame to prevent the discharged air   250 or more  Only two units can be installed for
             from being bypassed.                               this series.
            2  Series installation (2 or more)                 (D) Double-decker installation
             The relations between H, A and L are   500 or less  1  Obstacle on the discharge side     250 or
             as follows.                                         Close the gap Z (the gap between the upper an lower  more  Drain piping construction   dimension
                                                                 outdoor units) to prevent the discharged air from being
                                                    1000 or more  bypassed.
                                                                 Don not stack more than two units.
                                               250 or
                   Set the stand as:           more
             Close the bottom of the installation
             frame to prevent the discharged air
             from being bypassed.                                                                      1000 or more
             Only two units can be installed for                2  Obstacle on the suction side
             this series.                         300 or more    Close the gap Z (the gap between the upper an lower
                                                                 outdoor units) to prevent the discharged air from being
                                                                 bypassed.
               Pattern 2                                         Don not stack more than two units.
           When the obstacle on the discharge side is lower                                           250 or   Drain piping construction   dimension
           than the unit:                                                                             more
           (There is no height limit for obstructions on the
           intake side.)
           No obstacle above
                                                               (E)  Multiple rows of series installation    300 or
                                                                                                          more
            1  Stand-alone installation                           (on the rooftop, etc.)
                                                 100 or more
                                                               1  One row of Stand-alone installation
                                              500 or more
            2  Series installation (2 or more)

            The relations between H, A                                                                   100 or more
            and L are as follows.             250 or more                                           2000 or more
                                                 250 or more
                                                                                             200 or more
                                                                                           1000 or more
                                                                2  Rows of series installation (2 or more)
                                                                 The relations between H, A and L are as follows.
             Obstacle above, too
              1  Stand-alone installation     1500 or more
                                                                           Can not be installed
             The relations between H, A and L are
             as follows.
                                        500 or less                                                  250 or more
                    Set the stand as:               1000 or more                                        250 or more
             Close the bottom of the installation
             frame to prevent the discharged air
             from being bypassed.

                                                                                                      3000 or more
                                               1000 or more                                      600 or more
                                                                                              1500 or more






                                                                                                        3D089310A