Case study


         Replacing a gas boiler with a Daikin Altherma hybrid
         heat pump means saving on running costs for both space

         heating and domestic hot water supply.




          A running costs comparison is made below based on parameters for a typical Belgian winter.
          As a result of the hybrid principle, the most cost-efficient operation will be used no matter
          the ambient outdoor temperature.




                                                                               2000  A  100% use of gas boiler
                                                                               1800  B   Heat pump + gas boiler
                                                                                     C   100% use of heat pump
           Heat consumption (kWh /°C)                                          1200
                                                                               1600
                                                                               1400


                                                                               1000
                                                                                800
                                                                                600
                                                                                400
                                         B                   C
                                                                                200
                     A
                                                                                 0
                             -7                0                       15   °C

            +35% efficiency (space heating) compared to existing condensing gas boiler




                              Daikin altherma    New        Existing
                             hybrid heat pump  gas condensing boiler gas condensing boiler

                                            Space heating

          Energy supplied by HP  12,800 kWh
                                                                        Conditions
          HP efficiency         3.64 Scop
          Energy supplied by gas boiler  6,700 kWh  19,500 kWh  19,500 kWh  Heat load                  16 kW
          Space heating efficiency  90%        90%            75%       Design temperature             -8°C
          Running costs         1,220 €        1,520 €       1,820 €    Space heating off temperature  16°C
                                                                        Maximum water temperature      60°C
                                            DHW HEATING
                                                                        Minimum water temperature      38°C
          Energy supplied by gas boiler*  3,000 kWh  3,000 kWh  3,000 kWh  Gas price                 0.070 €/kWh
          DHW heating efficiency*  90%         80%           65 %       Electricity price (day)      0.237 €/kWh
          Running costs*         230 €         260 €         320 €      Electricity price (night)    0.152 €/kWh
                                               TOTAL                    Total space heating requirement  19,500 kWh
          Running costs         1,450 €        1,780 €       2,140 €    Total DHW heating requirement (4 persons)  3,000 kWh

          * for combi-boiler, no separate domestic hot water tank

                  Yearly savings:
                  for space heating and domestic hot water


           -19%   versus new gas condensing boiler                  330 €/year
           -32%   versus existing gas condensing boiler             690 €/year