Page 150 - General Catalogue
P. 150
EGSA(H/X)-D9W
Daikin Altherma 3 GEO
Ground source heat pump for heating,
cooling & hot water
› Top-level seasonal efficiency thanks to our inverter heat pump
technology providing the highest savings on running costs
› Delivering temperatures up to 65°C at high efficiency,
the R-32 Daikin Altherma 3 GEO is suitable for underfloor
heating/cooling, fan coils and radiators
› Integrated indoor unit: all-in-one floor standing unit including
the stainless steel domestic hot water tank saves space BRC1HHDW
and installation time
› The unit has a similar footprint when compared
to other household appliances
› Reversible heat pump, allowing heating and cooling EGSAH-D9W
A +++ A + 65°C
A ++ L A
011-1W0337
011-1W0338 A + B
A
Indoor Unit EGSA H06D9W X06D9W(G) C H10D9W X10D9W(G)
Heating capacity Min. kW 0.85
3.34
Nom. kW B D 5.48
Max. kW 7.98 9.55
Power input Nom. kW 0.7 1.12
COP C E 4.89
4.74
Space heating Average General ŋs (Seasonal space % 150 153 160 162
climate water heating efficiency) D F
outlet 55°C Seasonal space heating eff. class A+++
Average climate General ŋs (Seasonal space % 214 219 210 213
water outlet heating efficiency) E G
35°C Seasonal space heating eff. class A+++
Domestic hot water heating General Declared load profile F L
Average ŋwh (water heating efficiency) % 117
climate Water heating energy efficiency class A+
Space cooling UFH General SEER - G 15 - 15
Pdesign kW - 8 - 8
Fan Coil General SEER - 14 - 14
Pdesign kW - 8 - 8
Casing Colour White or Silver-grey
Material Precoated sheet metal
Dimensions Unit HeightxWidthxDepth mm 1,891x597x666
Weight Unit kg 222
Tank Water volume l 180
Insulation Heat loss kWh/24h 1,2
Corrosion protection Pickling
Operation range Installation space Min.~Max. °C 5 / 35
Brine side Min.~Max. °C -10 / 30
Heating Water side Min.~Max. °C 5 / 65
Domestic hot Water side Min.~Max. °C 25 / 60
water
Refrigerant Type R-32
GWP 675
Charge kg 1.70
Charge TCO2Eq 1.15
Sound power level Nom. dBA 39.0 41.0
Sound pressure level at 1 meter Nom. dBA 27.0 29.0
Power supply Name/Phase/Frequency/Voltage Hz/V 3~/50/400 or 1~/50/230
Current Recommended fuses A 3P 16A or 1P 32A
Options
Type Material name
Remote user interface BRC1HHDAK/S/W
Room thermostat (wired) EKRTWA
Room thermostat (wireless) EKRTR1
Controls
Cascade control EKCC8-W
Gateway for cascade controller DCOM-LT/IO
Gateway (Modbus) DCOM-LT/MB
Demand PCB EKRP1AHTA
Adapter
Digital I/O PCB EKRP1HBAA
Remote indoor sensor KRCS01-1
Sensor External sensor for room thermostat EKRTR1 EKRTETS
Current sensors EKCSENS
PC cable EKPCCAB4
Ground source filling kit KGSFILL2
Hydromodule replacement EKGSHYDMOD
Others
Separate power supply BUH EKGSPOWCAB
Magnetic filter Fernox K.FERNOXTF1
Magnetic filter Fernox K.FERNOXTF1FL
148