Page 162 - General Catalogue
P. 162

Applications




          1.   Standard hybrid operation



          With this application, the system works in a perfect   Outdoor                    Indoor
          balance between the gas boiler and the heat pump
          to provide space heating and domestic hot water.                         EHY2KOMB-A
          Here, the boiler is able to heat directly the water
          without a tank.
                                                                                                    User interface
                                                      EJHA-AV3











          1.1.  Standard hybrid operation with a tank



          In this application, a domestic        Outdoor                               Indoor
          hot water tank can be added
          if the system needs to provide                                                       Watertank
          high quantity of domestic hot
          water produced either by the                                 EHY2KOMB-A
          heat pump or by the boiler.







                                        EJHA-AV3                                                    User interface

                                                                         Motorised
                                                                         3-way valve








          2..  Add-on operation



          Daikin Altherma H Hybrid               Outdoor                               Indoor
          outdoor unit can be combined
          with an existing boiler. In such
          application, the system works
          in bivalent operation, meaning
          that this is strictly the heat pump                       Non-return valves                User interface
                                                                    (field supply)
          or the boiler that is providing
          the required heat while in the
          standard applications, both can   EJHA-AV3                          Third-party Gas boiler
          work at the same time.








                                                                       Pump

          160
          160
   157   158   159   160   161   162   163   164   165   166   167